RS-485 control command

RS-485 command table files


   CCTV camera connected with WJ-GXE100 is controlled with RS-485 communication.
   Pre-installed protocols in WJ-GXE100 are Panasonic, Pelco-D and Pelco-P.
   In other cases, select [Custom] for [Protocol] on the [RS485] tab of the
   [image] page and upload the command table with FTP to the unit.

   As a default setting, Panasonic command table files for PT control "SPEED_256"
   (velocity resolution: 256) for CCTV cameras have already stored in WJ-GXE100.
   PT for discontinued models as of Feb, 2013 may not be controlled. In this case,
   select [Custom] for [Protocol] on the [RS485] tab of the [image] page, and refer to
   the following instructions and upload the command table to WJ-GXE100.


   - PT control "SPEED_16" (velocity resolution: 16) for CCTV cameras
       WV-CS85x series except for WV-CS85xA/B series
        WV-CW86x series except for WV-CW86xA/B series
      Available command table file name: RS485_pana16\upload\camera_serial0.conf

   - PT control "SPEED_2" (velocity resolution: 2) for CCTV cameras
       WV-CSxxx/CWxxx series except for models above.
        WV-CS85xA/B, WV-CW86xA/B, WV-CS95x, WV-CW96x, WV-CW97x
       WV-CZ35x series
       WV-CZ36x series
      Available command table file name: RS485_pana2\upload\camera_serial0.conf

   - PT control unavailable for CCTV cameras
       WV-CWxxx series: Vandal resistant camera
       WV-CPxxx series: Box-type camera
       WV-CPRxxx series: Box-type camera
       WV-CFxxx series: Dome-type camera
       WV-CLxxx series: Ultra-high sensitivity camera
       WV-CLRxxx series: Ultra-high sensitivity camera

   - Upload procedure of command table
      1. Download above-mentioned command table file from Panasonic support website
         to PC as a zip file.
      2. Unzip the downloaded zip file on PC.
      3. Run [upload.bat] in [RS485_panaxx] folder created after unzipping.

         WJ-GXE100 is rebooted after uploading of command table.

     Note: - Run [upload.bat] after following configuration:
               1. Setup IP address of IPv4 as 192.168.0.10 on [Network] tab of [Network] page.
               2. Select "Allow" for [FTP access to unit] on [Network] tab of [Network] page.
               3. Check the default administrator's ID/Password: admin[1]/12345 is valid on
                  [User auth.] tab of [User mng.] page.
               4. Select [Custom] for [Protocol] on [RS485] tab of [image] page.

                  WJ-GXE100 is rebooted after the setting.

           - Setup [Unit address] in hex notation on [RS485] tab of [image] setting.

           - Command table settings are initialized when the unit is initialized.
              In this case, upload the command tables again as necessary.

           - A file name of command table:[camera_serial0.conf] is only valid.
              When the file name is changed, the unit cannot be operated.



Writing/editing of RS485 command table


     To control other than Panasonic CCTV camera, Pelco-D and Pelco-P compatible cameras,
     command tables are necessary to write/edit and upload to the unit.
     We do not take any responsibility for written/edited command tables.


     Following information is just for reference.

     A file name of command table:[camera_serial0.conf] is only valid.
     When the file name is changed, the unit cannot be operated.


     <COMMON>
      [1] Lines begin with [=] are commentary. They have no effect for RS485 control to the unit.
      [2] File size for RS485 command table is limited not to exceed 20KB each file.


     <CAMERA INFORMATION>
      - CAMERA TYPE
          Set [PANASONIC] for Panasonic CCTV cameras, [PELCO D Protocol] for Pelco-D
          compatible cameras.
          [RON:7] command is transmitted when [PANASONIC] is set and [2-line] is selected as
          RS485 communication.

      - VER
      - PAN_TILT_SPEED
      - ZOOM_SPEED
          These have no effects for RS485 control to the unit.
          These are intended for administrative information in editing RS485 command table.

      - DATA_FORMAT
          Set [TEXT] for ASCII data communication, or [BIN] for binary data communication.

      - ADDRESS
          This has no effect for RS485 control to the unit.
          Set [Unit address] in accordance with a unit number of controlled CCTV camera.


     <SET UP A PRESET POSITION>
     <SET UP A AUTO FOCUS>
     <SET UP A AUTO PAN MODE>
     <SET UP A BLACK AND WHITE(COLOR) MODE>
     <SET UP A MAINTENANCE MENU>
     <SET UP A PAN&TILT&ZOOM&FOCUS&IRIS>
     <OTHER>

        - Left part(hereinafter, command key) and right part(hereinafter, data part) should be
           connected by [=].
        - When the unit is operated, relevant command keys are selected.
        - Command keys cannot be modified.
        - Data part which corresponds to the selected command key will be transmitted. When any changes are required in
           transmitted data, edit the data part.
        - [%x…%] means hexadecimal. For example, [%x02%] means [STX(0x02)].
        - Following alternative characters may be set for variable number as data parts.
             %addr%        Replaced by [Unit address] in setup menu
             %pn4b%        Replaced by [PAN speed] as 4-bit value: 1 character
             %pn8b%        Replaced by [PAN speed] as 8-bit value: 2 characters
             %tl4b%         Replaced by [TILT speed] as 4-bit value: 1 character
             %tl8b%         Replaced by [TILT speed] as 8-bit value: 2 characters
             %zm4b%        Replaced by [ZOOM speed] as 8-bit value: 2 characters
             %pr8b%         Replaced by [PRESET number] as 8-bit value: 2 characters
             %pr12b%       Replaced by [PRESET number] as 12-bit value: 3 characters
             %bcc(x,y)%    Replaced by [CHECKSUM]. x means start position, y means end position.
                           x and/or y can be omitted

        - Operation may be added in alternative characters as necessary.
             For example, [%pr8b+0xFF%]
               RS485 control specification of Panasonic CCTV cameras requires [A-1] command
               transmission to move to [PRESET A], thus [%pr8b+0xFF%] is used by adding [0xFF].



Command transmission in serial port (RS485 compliant)


     WJ-GXE100 has a following function: Data received from PC in UDP 52000 port can be sent to
     serial port (RS485 compliant). Arbitrary command from PC may be dynamically transmitted to
     analog camera. [RS485] settings on [RS485] tab of [Camera] page are applied as communication